PT. Petirindo Jaya Abadi

sql
Cubicle - SM6-24 Schneider Electric
Hover to Zoom

Last Updated
08 Jun 2020
Country Origin
Indonesia
Minimum Order
1 Unit

Specification of

Sell ​​Cubicle Metering Panel - SM6-24 Schneider Electric

Switch and fuse protection cubicles

1 switchgear: switch-disconnector and earthing switch in an enclosure filled with SF6 and satisfying "sealed pressure system" requirements.
2 busbars: all in the same horizontal plane, thus enabling later switchboard extensions and connections to existing quipment.
3 connections: accessible through front, connection to the lower switch-disconnector and earthing switch terminals (IM cubicles) or the lower fuse-holders (PM and QM cubicles). This compartment is also equipped with an earthing downstream switch from the MV fuses for the protection units.
4 operating mechanism: contains the elements used to operate the switch disconnector and earthing the switch and actuate the corresponding indications (positive break).
5 low voltage: installation of a terminal block (if motor option installed), LV fuses and compact relay devices. If more space is required, an additional enclosure may be added on top of the cubicle. Options: please, refer to the chapter "Characteristics of the functional units".

SF6 circuit breaker cubicles

1 switchgear: disconnector (s) and earthing switch (es), in enclosures filled with SF6 and satisfying "sealed pressure system" requirements.
2 busbars: all in the same horizontal plane, thus enabling later switchboard extensions and connections to existing equipment.
3 connection and switchgear: accessible through front, connection to the downstream terminals of the circuit breaker.
Two circuit breaker offers are possible:
 • SF1: combined with an electronic relay and standard sensors (with or without an auxiliary power supply)
 • SFset: autonomous set equipped with an electronic protection system and special sensors (requiring no auxiliary power supply).
4 operating mechanism: contains the elements used to operate the disconnector (s),
the circuit breaker and the earthing switch and actuate the corresponding indications.
5 low voltage: installation of compact relay devices (Statimax) and test terminal boxes. If more space is required, an additional enclosure may be added on top of the cubicle.

Options: please, refer to the chapter "Characteristics of the functional units".

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Selling Complete Lightning Protection

Selling Lightning Protection - Lightning often appears together with the rain sometimes the nipple can also appear even without rain. Lightning is usually seen with flashes of blinding light accompanied by a frightening sound that makes you afraid and makes you want to close your ears. Lightning is a natural occurrence of a process of electron transfer of positive charges and also negative charges. This lightning also has a high speed level and is also able to damage objects that pass through it whether inanimate objects such as trees, wood, poles, houses or living objects such as animals and humans. Therefore this lightning is very important to know how to overcome and overcome it.

With the existence of this increasingly advanced technology has emerged found lightning rods or anti-lightning devices, this system of lightning rods is a system specifically designed to flow lightning and directs it to the surface of the earth without damaging objects around it. In this system usually has 3 important circuits used including: 1. Petior rod, 2. conductor wire, 3. Grounding. In the way this system works it serves to stabilize the electric current obtained from lightning and drain it to grounding without damaging the surrounding objects.

This lightning rod also has many types that have been discovered by scientists including the following:
1. Franklin Lightning Protection (conventional),
2. Conductor threaded method,
3. Faraday cage method,
4. Electrostatic air terminals
and many others. As this technology develops, the system on lightning rods is always updated to a system that is safe and cost-effective and can certainly be relied on for your needs.

Who needs to use this Lightning Rod?
everyone can buy and use this lightning rod because everyone can potentially be exposed to lightning especially if you live in a high place such as an office building, multi-storey housing, schools or institutions, hospitals, hotels and manufacturing and other industries.

we have experienced since 2012 selling high-quality lightning rods that can be relied upon and have many customers from various fields of agencies, companies and other industries. So if you are looking for a company that sells lightning rods, we are the right company for you. Please choose and find the lightning rod that you are looking for if you want to go to our place, we are ready to serve it, we also sell a variety of other electrical equipment.

 

Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot